Top Fencing Companies in Severance, CO, 80524 | Compare & Call

There are 222 fencing companies server in Severance CO

Castillo’s Handy Service & Remodel

Castillo’s Handy Service & Remodel

Evans CO 80634
Handyman, Fences & Gates, General Contractors

Castillo’s Handy Service & Remodel is a trusted handyman and general contractor serving Evans, CO, and the surrounding Weld County area. Specializing in appliance installation, door repair, flooring, ...

Fence Works

Fence Works

502 Mallard Dr, Severance CO 80546
Fences & Gates

Fence Works serves Severance, CO, providing expert fence and gate solutions for local homes. Many residences in neighborhoods like Highland Meadows and near Severance Middle School face issues with wa...

« Previous PagePage 23 of 23Next »


Estimated Fencing Costs in Severance, CO

Emergency Fence/Gate RepairStorm / Security Response
$309 - $414
Wood Privacy Fence (Per LF)Estimated Range
$29 - $44
Vinyl / PVC Fencing (Per LF)Estimated Range
$39 - $59
Chain Link Installation (Per LF)Estimated Range
$19 - $29
Aluminum / Ornamental (Per LF)Estimated Range
$44 - $69
Standard Driveway Gate InstallEstimated Range
$1,104 - $1,479

Methodology: Estimates are dynamically generated using localized construction labor multipliers derived from 2025 BLS OEWS (SOC 47-4031) data for Severance. Prices reflect standard commercial/residential material specs and labor options adjusted for 2026 economic projections.

FAQs

What fence materials work best for Severance's soil and insect conditions?

Material compatibility is critical given the moderate soil corrosivity index and slight to moderate termite risk. Pressure-treated wood rated for ground contact is standard. All fasteners and metal components must be G90 galvanized steel or better to prevent rust streaks and premature failure. Composite or vinyl materials offer high resistance to both corrosion and insect damage in this environment.

What are the height and placement rules for a Severance fence?

Severance zoning enforces a 4-foot height limit in front yards and a 6-foot limit in rear yards. The standard setback regulation is 0 feet, allowing installation directly on the property line. Corner lots must maintain a visibility 'sight triangle'—a clear zone at intersections—which is critical for safety near high-traffic corridors like CO-392. Fences cannot obstruct driver sightlines within this triangle.

How soon can a project start after approval?

Mobilization typically occurs within 5-7 business days post-contract and permit issuance. Our standard dispatch route from the Severance Community Park area uses CO-392 for efficient access across town, ensuring a 15-25 minute response time for initial consultations and job site visits. This logistics plan minimizes delays in material delivery and crew arrival.

Why do fence posts in Severance need deep concrete footings?

The 36-inch frost line depth in Weld County determines footing stability. Posts set above this depth will lift from frost heave during winter freeze-thaw cycles, causing permanent misalignment and failure. The 2021 International Residential Code (IRC) Section R403.1.4 mandates footings extend below the frost line. Posts in the Severance Town Center neighborhood must meet this standard to resist soil movement.

What are the required steps before digging fence post holes?

Contact Colorado 811 at least three business days before excavation. This free utility locate service marks public underground lines. Hitting an unmarked line in a neighborhood like Severance Town Center can cause service outages, major repair liabilities, and fines. The fencing contractor typically manages the associated Town of Severance permit office paperwork, which requires the 811 ticket number for approval.

What are my legal duties to my neighbor when building a fence in Severance, CO?

Colorado Revised Statute 35-46-102 defines a partition fence as a shared boundary. The law requires notifying the adjoining landowner in writing before building or replacing such a fence. In Severance, this 2026 legal requirement is essential for establishing shared maintenance costs and preventing disputes. Failure to provide notice can result in liability for the full construction cost.

How do wind loads affect fence design here?

Severance has a V-ult design wind speed of 115 mph, per ASCE 7-22 standards. This engineering rating dictates structural requirements to survive peak storm season gusts. Proper design involves calculating wind pressure to determine maximum post spacing, concrete footing mass, and bracket strength. A fence built to lower wind ratings will likely fail during high-wind events common to the plains east of CO-392.

Can I integrate a smart gate with my pool fence to meet code?

Yes. Modern connected access control systems can integrate with physical fencing to meet both security and safety codes. The International Residential Code (IRC) Appendix AG and International Building Code (IBC) 3109 require pool barriers to have self-closing, self-latching gates. An IoT-enabled smart latch can provide remote access control while maintaining the constant mechanical latch action required by Colorado law, addressing modern liability standards.